Ce dispositif est le micro-frère du Float-A-lyzer, aussi pratique et efficace, pour dialyser des micro-volumes de 10-100µl ! La membrane de dialyse, en cellulose régénérée, forme un sac sans embase, qui maximise le rapport surface/volume et donc la vitesse de dialyse. |
|
|
|
Microdispodialyser
Catalog Numbers: |
|
Molecular Weight Cut-Off |
|||||
|
Volume |
3.5kD |
8kD |
15kD |
25kD |
60kD |
|
10µl |
|||||
|
50µl |
|||||
|
100µl |
|||||
|
24 unités par boîte |
|||||
|
10µl |
|||||
|
50µl |
|||||
|
100µl |
|||||
|
48 unités par boîte |
|||||
|
10µl |
|||||
|
50µl |
|||||
|
100µl |
|||||
|
Kits d’essai et échantillons sur demande |
|||||
|
Concentrez aisément vos échantillons dialysés!
Ce
gel, formé de polyacrylate/polyalcool, absorbe l’eau au travers de la
membrane de dialyse, jusqu'à 1000 fois son poids, concentrant l’échantillon
dialysé sans le contaminer. Il augmente de volume, restant insoluble,
sans devenir collant, ce qui facilite la récupération du dispositif de
dialyse. Il s’utilise avec tous les dispositifs de dialyse et les tubes
conventionnels de dialyse. Utilisé
avec le Float-A-lyser de cutoff 15Kda, un volume de 5ml est réduit à
0.5ml en 90min avec 10g de spectra-gel.
|
Avant concentration |
Après concentration |
|
The Spectra/Por Heavy Metals Cleaning solution can be used to remove the heavy metal contamination found in traditional regenerated cellulose membranes. This chelating wash can be used to remove these heavy metals in situations where they would interfere with later analysis of the dialysate or the retentate, especially where they would interfere with protein function. Each heavy metals cleaning kit, part number 132908, can clean several hundred feet of tubing.
|
Instructions for Use:
|
|
Spectra/Por series 1 through 6 contain about 0.1% sulfur remaining from the manufacturing process. This may be removed if its presence might interfere with the subsequent use of the dialysate or retentate. Each sulfide removal kit, part number 132906, can clean several hundred feet of tubing.
|
Note:
For ease of use, we recommend
Spectra/Por 7 membranes, which are already treated to remove the
contaminants, or BioTech membranes which are made from chemically pure
cellulose, or type F (PVDF) membrane wich are devoided of sulfu and heavy
metals. Note: Trace elements found in Spectra/Por RC series 1 through 6 are (ppm): Calcium < 0.02, Chromium 0.1–0.2, Copper 0.8–1.2, Iron 20–60, Lead 2.0–6.0, Magnesium 0.1–0.3, Nickel 1.3–1.7, and Zinc 1.5–5.0. |
||||||
|
Instructions for Use:
Related Products or Documents: CelluSep dialysis membranes |
|||||||
|