Flash Chromatography |
|
Flash Cartridges : PuriFlash FM-Series™ |
|
PuriFlash FM-Series Cartridges for greater value with improved performance |
|
PuriFlash FM-SeriesTM Cartridges replace glass columns in lab scale purification systems without changing method protocols. These disposable cartridges come in five sizes with samples loads from 2 g to 70 g. They are pre-packed with sorbent using proprietary Gradient Free CompressionTM technology. This technology substantially reduces particle interstitial spacing in the column. The cartridge performs better by providing greater interaction with less channeling for reproducible sharp peaked separations. You get better results when your flash cartridge performs better.
|
|
|
Cartridge |
FM-15 |
FM-25 |
FM-70 |
FM-70 |
FM-150 |
FM-150 |
FM-150 |
|
Dimensions L X D |
3.6" x 0.7" (9 x 1.8 cm) |
3.9" x 0.9" (9.9 x 2.3 cm) |
6" x 1.2" (15.4 x 3 cm) |
6" x 1.2" (15.4 x 3 cm) |
6.8" x 1.6" (17 x 4 cm) |
6.8" x 1.6" (17 x 4 cm) |
6.8" x 1.6" (17 x 4 cm) |
|
Bed Mass (g) |
2 |
5 |
10 |
20 |
25 |
50 |
70 |
|
Sample Load DCV = 6* |
50 -100 mg |
125 - 500 mg |
250 - 500 mg |
500 mg - 1 g |
900 mg - 1.25 g |
1.5 g - 2.5 g |
2.5 g - 3.5 g |
|
Sample Load DCV = 2* |
10 - 50 mg |
80 -125 mg |
125 - 250 mg |
250 - 500 mg |
500 - 900 mg |
900 mg - 1.5 g |
1.0 - 2.5 g |
|
Sample Load DCV = 1* |
2 -10 mg |
10 - 80 mg |
50 - 125 mg |
100 - 250 mg |
250 - 500 mg |
250 - 900 mg |
250 mg - 1 g |
|
Column Volume (mL) |
15 |
25 |
70 |
70 |
150 |
150 |
150 |
|
Sorbent |
Silice - C18 - C18U - C8 - NH2 - Diol - Alumina Acidic - Alumina Basic - Florisil - Alumina Neutral |
||||||
|
Packing Method |
Gradient Free Compression |
||||||
|
Flow rate (mL/min) |
5 |
5 |
15 |
15 |
50 |
50 |
50 |
|
Pressure (PSI) |
100 PSI Maximum |
||||||
|
Bed Length (cm) |
2.0 |
3.0 |
3.3 |
6.4 |
4.0 |
8.2 |
12.4 |
|
Bed Diameter (cm) |
1.6 |
2.0 |
2.7 |
2.7 |
3.8 |
3.8 |
3.8 |
|
L/D Ratio |
1.25 |
1.5 |
1.2 |
2.4 |
1.1 |
2.2 |
3.3 |
|
Cartridge Material |
Polyethylene, low extractible, USP Class VI |
||||||
|
Frit Material |
Polyethylene, low extractible |
||||||
|
* Sample Load Calculation: DCV = 1/Rf1 - /Rf2 |
|||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Please contact interbulk@interchim.com or your local distributor for custom cartridges. |
|