DAB Peroxidase Substrate System - Code E885 Directions for Use |
| Contents: DAB Substrate Tablets (Code E733) Peroxidase Solution (Code E882) Mixing/Dispensing Bottle Each Tablet will yield 10 ml of substrate solution, enough to effectively detect 50cm2 of membrane or about 20 slides. Step 1: Drop one tablet into the mixing/dispensing bottle, and add 10 ml deionized water. Cap bottle and shake gently until the tablet dissolves, about 2-3 minutes. Step 2: Using the attached dropper cap, add one drop of peroxidase solution to the dissolved substrate tablet. (Caution: Do not use the dropper cap from the mixing bottle to aliquot the peroxidase solution. Doing so may contaminate the peroxidase solution and decrease the shelf-life of the reagent.) Step 3: Cap the mixing bottle and invert gently to mix. Step 4: Using the dispensing dropper, layer the prepared substrate solution onto the membrane or slide. Generally, 1 ml of substrate will be sufficient for detecting 5-10 cm2 of membrane. 0.5 ml of substrate is sufficient for most slides. Step 5: Unused Substrate Solution can be stored at 4C (refrigerated) for up to 6 hours. |
|
|
211 Bis Avenue Kennedy - BP 114003103 Montluçon cedex - France tel (33) (0) 4 70 03 88 55 fax(33) (0) 4 70 03 82 60 http://www.interchim.com |
Vos contacts: Etienne Boireau - Olivier Cadas - Olivier Alméras hot line 33 (0) 4 70 03 73 06 |
|